« »

超滤/微滤膜表征

Welkin | 2009/11/16 | 分类:膜技术 | 标签: | 浏览:6次

Pore size

Molecullar weigh cut-off using dextran or polyethylene glycol (PEG) rejection. The pore size is determine as the molecular weigh of particle that can be rejected 90% by membrane. The filtration is conducted by filtering the serries of differend dextran MW solution. The rejection profile than defined by the linearization of the rejection-MW curve. Normaly the concentration of the dextran is less than 2% w/w. 
Procedure of PEG rejection test (A. D. Sabde et al. [1997]):
Reagents 
  1. 5% w/v BaCl2 in 1 N HCl (100 ml)
  2. 100 ml of 2% KI (w/v)  + 1.27 g I2 –> This mixture than dilluted 10 times.
Procedure:
  1. Add 1 ml reagen 1 to 4 ml sample —>  (I)
  2. Add 1 ml reagen II to  solution I —> (II)
  3. Allow the color development for 15 minutes at room temperature
  4. Read the absorbtion using spectrophotometer at 535 nm againt reagent blank
Note: To get the concentration value, the calibration curve is required.


Pore size distribution
Bubble  
Porosity
Surface structure
 
该日志于 2009-11-16 16:24 由 Welkin 发表在 膜技术 分类下. 你可以发表评论。除了可将此日志以保留源地址及作者的情况下引用到你的网站或博客,还可以通过RSS 2.0订阅这个日志的所有评论。

赞助商

0 条评论 !

  • 目前还没有评论,请在下面表格发表您的评论。

发表评论